RECD Compliance for Diesel Generators: Complete CPCB Guide (2026)

Understanding RECD compliance for diesel generators is becoming increasingly important for organizations that operate diesel generator sets and need to manage emissions from existing equipment. However, compliance should not be approached as simply purchasing an emission-control device and installing it on any available DG set. The correct approach involves identifying the generator and engine specifications, checking the applicable requirements, selecting an appropriate retrofit emission control device, verifying supporting documentation, and maintaining the system correctly after installation.

The Central Pollution Control Board (CPCB) has published a specific system and procedure for emission compliance testing of Retrofit Emission Control Devices (RECDs) for diesel power-generating-set engines up to 800 kW gross mechanical power. The procedure was revised on July 24, 2023.

What Is RECD Compliance?

RECD stands for Retrofit Emission Control Device.

It refers to an emission-control device designed for installation on an existing diesel power-generating-set engine. Instead of replacing an entire operating generator, a retrofit system can be evaluated as an additional emission-control solution for applicable existing DG sets.

However, the word “compliance” should be used carefully.

An RECD product may have specific certification or testing information, but that does not automatically mean that every installation using that product satisfies every regulatory requirement.

Compliance can depend on factors such as:

  • DG-set specifications

  • Engine model

  • Engine power

  • Applicable phase

  • RECD model

  • Installation configuration

  • Applicable regulatory requirements

  • State or local requirements

  • Operation and maintenance

Therefore, product selection and regulatory verification should be treated as connected but separate steps.

What Does CPCB's RECD Framework Cover?

CPCB's published procedure establishes a system for emission compliance testing of RECDs for diesel power-generating-set engines up to 800 kW gross mechanical power.

The framework provides a technical basis for evaluating retrofit emission-control devices.

CPCB also publishes a list of manufacturers certified for RECDs applicable to diesel genset engines up to 800 kW. The published list available from CPCB is organized by engine-power range and indicates applicability for Phase I, Phase II or both, along with the relevant certification agency.

This is important because an RECD should not be selected solely based on the generator's kVA rating.

Start With Your Generator's Technical Information

Before purchasing an RECD, collect the basic information about the DG set.

At minimum, record:

  • DG-set manufacturer

  • Engine manufacturer

  • Engine model

  • Engine serial number

  • Generator capacity in kVA

  • Gross mechanical engine power in kW

  • Phase, where applicable

  • Manufacturing details

  • Exhaust-pipe configuration

This information gives the supplier and technical team a basis for evaluating the proposed RECD.

Why kVA Alone Is Not Enough

A common purchasing mistake is to identify a generator only by its kVA rating.

For example, saying:

“We have a 500 kVA DG set.”

may not provide enough technical information.

CPCB's published RECD manufacturer list specifies applicability using ranges of in-use diesel genset engine power in kW, rather than relying only on generator kVA.

Therefore, confirm the engine's gross mechanical power before selecting a product.

Understand Phase Applicability

Phase classification is another important consideration.

CPCB's published RECD manufacturer list identifies whether particular certified products are applicable to Phase I, Phase II or both.

Generator owners should therefore determine the applicable phase for their equipment and then verify that the proposed RECD has documented applicability for that category.

Do not assume that a product suitable for one phase automatically applies to another.

How to Evaluate an RECD Product

A proper evaluation should go beyond a supplier's brochure.

Request information including:

  • Manufacturer name

  • Exact RECD model

  • Product identification

  • Applicable engine-power range

  • Applicable phase

  • Certification/test information

  • Certification agency

  • Installation requirements

  • Maintenance instructions

CPCB's published material provides for identification of the RECD manufacturer, family, type/model and identifying part numbers within its technical certification documentation.

This makes product-specific documentation an important part of the purchasing process.

Check the Certification Agency

CPCB's published manufacturer list identifies certification agencies associated with the listed RECD products, including agencies such as ICAT and ARAI.

When reviewing a supplier's documentation, confirm that:

  • The manufacturer name matches.

  • The RECD model can be identified.

  • The applicable power range is clear.

  • The phase applicability is clear.

  • The certification information corresponds to the product being offered.

This is more reliable than accepting a general statement such as “CPCB approved” without supporting information.

Installation Is Part of the Compliance Picture

Selecting an appropriate RECD is only one stage of the process.

The physical installation also needs technical attention.

Before installation, examine:

Exhaust Configuration

Check:

  • Exhaust-pipe diameter

  • Existing silencer arrangement

  • Available space

  • Flange configuration

  • Pipe routing

  • Supports

  • Access for maintenance

Engine Considerations

The installation should also be evaluated against the applicable engine requirements.

One parameter specifically addressed in CPCB's RECD technical procedure is exhaust back pressure.

Therefore, the proposed retrofit should not simply be attached to an exhaust line without considering the overall engine-exhaust arrangement.

Don't Treat Every DG Set as Identical

A facility may have several generators with similar kVA ratings.

That does not necessarily mean that every engine has identical requirements.

Two generators rated at the same kVA could differ in:

  • Engine manufacturer

  • Engine model

  • Engine power

  • Emission category

  • Exhaust configuration

  • Phase

  • Installation conditions

For this reason, large facilities should prepare an individual equipment record for every DG set before beginning an RECD project.

Operation and Maintenance Matter

Installing an RECD does not remove the need for proper generator maintenance.

The DG set itself should continue to be operated and maintained according to the engine manufacturer's applicable requirements.

The RECD should also be maintained according to the product manufacturer's instructions.

Depending on the system, maintenance may involve checking:

  • Sensors

  • Controller

  • Connections

  • Exhaust components

  • Mounting arrangements

  • Relevant replaceable components

The exact maintenance requirements should be obtained from the RECD manufacturer.

How to Check an RECD Supplier

Choosing the supplier should involve more than comparing prices.

Ask the supplier:

  1. Which exact RECD model is proposed?

  2. What engine-power range does it cover?

  3. Which phase is applicable?

  4. What certification/test documentation is available?

  5. Which certification agency is identified?

  6. What installation work is included?

  7. What maintenance is required?

  8. What is covered under warranty?

  9. Are spare parts available?

  10. What technical support is available after installation?

A supplier that can provide clear technical documentation is generally easier to evaluate than one offering only a generic product description.

What Is an RECD Manufacturer in India?

When searching for an RECD manufacturer in India, buyers should distinguish between a company that sells emission-control equipment and a manufacturer/product listed within CPCB's published RECD certification framework.

CPCB maintains a published list of manufacturers certified for RECDs applicable to diesel genset engines up to 800 kW. The list provides the manufacturer's name along with applicable engine-power ranges, phase applicability and certification agency information.

However, buyers should always check the latest official CPCB information rather than relying on an old list, sales brochure or third-party directory.

The important question is not simply:

“Is this company an RECD manufacturer?”

It is:

“Is the specific RECD product applicable to my particular DG-set application, and can the supplier provide the relevant supporting documentation?”

Genuine Documentation vs Marketing Claims

A genuine purchasing evaluation should be based on identifiable information.

Be cautious when a supplier uses phrases such as:

  • “100% CPCB approved”

  • “Suitable for every DG set”

  • “Universal RECD”

  • “Guaranteed compliance”

without providing product-specific documentation.

These statements should be clarified before purchase.

Ask for the relevant evidence and compare the product details with your actual DG-set specifications.

What About State-Level Requirements?

CPCB provides the national technical framework and publishes relevant information, but generator owners should not assume that one document answers every site-specific regulatory question.

Depending on the location and circumstances, requirements may also involve the relevant State Pollution Control Board (SPCB) or Pollution Control Committee (PCC).

Before finalizing a compliance project, verify:

  • Applicable national requirements

  • Current CPCB information

  • State-level requirements

  • Site-specific directions, if any

  • Generator-specific applicability

This is particularly important for facilities operating in regulated or environmentally sensitive locations.

Common Mistakes to Avoid

Several mistakes can make an RECD project unnecessarily complicated.

Choosing by kVA Alone

Generator kVA is useful, but technical product applicability should be checked against the engine information.

Buying Without Model Verification

A generic “RECD system” description is not enough. Identify the exact product.

Ignoring Phase

Phase applicability should be specifically checked.

Assuming Installation Is Universal

Existing exhaust arrangements can differ significantly between DG sets.

Accepting Old Certification Information

Always verify the current official information available at the time of purchase.

Ignoring Maintenance

A retrofit system needs appropriate operation and maintenance after installation.

Is RECD Compliance the Same for Every Generator?

No assumption should be made that every diesel generator has identical compliance requirements.

The applicable requirements can depend on the generator, engine, phase, installation, location and current regulatory framework.

Therefore, the safest approach is to evaluate the actual equipment rather than applying a generic internet checklist without verification.

How Aceget Can Support Your RECD Evaluation

For organizations considering an RECD retrofit, the first step should be a technical discussion based on the actual DG-set specifications.

Provide the engine model, power information and available exhaust details so the proposed solution can be evaluated appropriately.

A technically informed evaluation can help determine:

  • Whether an RECD solution is applicable

  • Which product configuration should be considered

  • What installation work may be required

  • What documentation should be reviewed

  • What maintenance and support may be needed

The final regulatory position should always be verified against the current official requirements applicable to the installation.

Final Thoughts

RECD compliance should be approached as a complete process rather than a single equipment purchase. Begin by identifying the DG-set engine and confirming its gross mechanical power. Then determine the applicable phase and evaluate an RECD product against its documented application range. CPCB's current published manufacturer list demonstrates that certified RECD products are associated with specific power ranges and Phase I/Phase II applicability. Next, review the relevant certification or test documentation, installation requirements and maintenance information. CPCB's published RECD procedure provides the technical framework for emission compliance testing of retrofit devices for diesel genset engines up to 800 kW gross mechanical power. Most importantly, avoid treating a general “CPCB approved” statement as automatic proof of compliance for every generator. The exact product, engine application, phase, installation and applicable regulatory requirements should be verified.

 

Enjoyed this article? Stay informed by joining our newsletter!