ICARELIFE Operating Room Control Panel (also called Surgical Control Panel) centralizes temperature, humidity, lighting, and medical gas alarm in a hygienic, user-friendly touch interface. Built with antibacterial materials, it ensures safe, efficient operation and seamless hospital system integration, enhancing OR workflow and precision control.
Features
Operation System: Android
32″ Capacitive Touch Screen LCD monitor
Operating Room Facility Control: Light 1, Light 2, Shadowless Light, Led light, Medical Door, X-ray View, Writing Desk.etc (on/off)
Environment Data Display & Control: Tempe, Humidity and HVAC data. etc. (through Modbus RS-485 protocol or directly connecting to sensor))
Medical Gas Display & Alarm
IT Power Supply Alarm, UPS Alarm, Fire Alarm, Filter Alarm, Room Pressure Alarm
Other Function: Music (Remote, Local and Bluetooth) Phone and Video Call
Functions
ICARELIFE operating theatre control panel demo
Option sensors
Siemens white temperature sensor with probe
Air Duct Humdity & Temp Sensor
Model: SIEMENS QFM1660
Relative Humidity Digital Output: DC 0–10V
Temperature Digital Output: DC 0–10V
Measurement Accuracy: <±0.8°C @ 25°C / ±5% r.h.
Applicable Temperature & Humidity Range: 0–50°C / 10–90% r.h. (Non-condensing)
Operating Voltage: AC 24V or DC 19-30V
Siemens temperature humidity and temp sensors
Air Room Humdity & Temp Sensor
Model: SIEMENS QFM 2068
Operating voltage: AC/DC 13.5…35 V
Measuring range, temperature: -15…50 °C
Measurement range humidity: 0…95 % r.h.
Measurement accuracy: 23 °C:23 % r.h., 0…95 % r.h.:±5 % r.h.
Time constant: 20s
Signal output temperature: DC 0…10V, DC 4…20mA, LG-Ni1000
Signal output humidity: DC 0…10 V, DC 4…20 mA
QFM 2030 Pressure Sensor
Differential Pressure Sensor
Model: SIEMENS QFM 2030
Operating Voltage: AC 24V or DC 13.5–33V
Signal Output: DC 0–10V
Zero Point Adjustment
Calibrated and Temperature-compensated Measurement Signal
Gas Pressure Sensor
Medical Gas Pressure Sensor
Measurement Range: -0.1MPa to 100MPa (Optional)
Operating Voltage: Universal for 220V and 380V
Accuracy: 1.6 Grade
Ambient Temperature: -40°C to 70°C
Relative Humidity: ≤85%
Measurement
FAQ
What is operating room control panel
An Operating Room Control Panel (OR Control Panel) is an integrated system designed to centralize and simplify the control of critical functions in a surgical environment. It provides a user-friendly interface for managing temperature, humidity, lighting, medical gas alarms, ventilation, and real-time clock settings. These panels enhance operational efficiency by offering touchscreen or button-based control, ensuring quick adjustments to maintain optimal surgical conditions. Built with antibacterial and durable materials, they comply with hospital hygiene standards, reducing contamination risks. Customizable to meet specific hospital requirements, an OR Control Panel seamlessly integrates with medical and building management systems, improving safety, workflow, and overall surgical precision.
Why chose ICARELIFE control panel
The ICARELIFE operating theatre control panel stands out due to its advanced functionality, intuitive design, and superior reliability. Here’s why customers prefer ICARELIFE over other suppliers:
1. Seamless Integration & Customization
• Supports multi-system integration, including HVAC, medical gas alarms, lighting, and surgical timing systems, ensuring smooth operation.
•Fully customizable interface to meet different hospital and cleanroom project needs.
2. Intuitive & User-Friendly Control
•Equipped with a large capacitive touchscreen (up to 32”) for quick and precise adjustments.
•Simple and ergonomic design reduces operator fatigue, improving efficiency in high-pressure surgical environments.
3. Superior Hygiene & Durability
•Built with antibacterial and easy-to-clean materials, reducing the risk of contamination in sterile environments.
•Sealed, dustproof, and waterproof design ensures longevity and minimal maintenance.
4. Reliable Performance & Safety Features
•Redundant system backup prevents failures, ensuring continuous operation.
•Real-time monitoring and alarms for temperature, humidity, and medical gas levels enhance safety and compliance with hospital standards.
With its cutting-edge technology, hospital-specific customization, and superior build quality, ICARELIFE’s Operating Room Control Panel provides a more efficient, reliable, and hygienic solution than competitors.
How to monitor the Humidity and Temp data ?
Option 1
By connecting the 3rd party option sensors, ICARELIF OR control panel room can demonstrate the humidity and tempature data in the operating room. As we mentioned above, we suggest SIEMENS QFM1660 to monitor operating room humidity and teamature data. To monitor room pressure difference, we suggest to use SIEMENS QFM2030. More info, you could refer to our OPTION SENSORS segment.
Option 2
By conecting with with hospital HVAC systems PLC system through MODBUS RS845 protocol, ICARELIFE OR control panel can both monitor and control the operating room humdity and tempature data for a accurate enviroment monitoring.
Can ICARELIFE control panel adjust the lighting dimmers in OR ?
Yes, It can. However, The standard configuration of the ICARELIFE Operating Room Control Panel is basic ON/OFF lighting control. Dimming functionality can be added upon request. To enable dimmer integration, customers must inform us of the lighting control protocol used in their system. The most commonly supported protocol is DMX 512, which we can integrate directly. DALI protocols are also possible, but compatibility testing is required before production. This ensures reliable performance and seamless integration with the hospital’s existing lighting infrastructure.

You must be logged in to post a comment.